| Sign In | Join Free | My chinacomputerparts.com | 
 | 
Brand Name : HNMC
Model Number : HEWE series
Place of Origin : China
MOQ : 1
Price : Negotiable
Payment Terms : L/C, T/T, Western Union
Supply Ability : 30 sets per month
Delivery Time : 30-45 days
Packaging Details : Wooden Package
Accuracy class : 2
Current Range1 : 1A, 5A
Voltage Range : 100V、100/√3V
Test Function : Ratio, Ratio error, phase angle error......
Percentage error : Less than 1.5%*FS
Display : big LCD
Digital Transformer Tester HEWE series CT PT Test Equipment Comparator
Technical Parameter
| Accuracy class | 2 | 
| Current range | 5A, 1A | 
| Voltage range | 100V,100/√3V | 
| Percentage Error | Less than 1.5%*FS | 
| Basic Error | |
| When testing CT PT error & impedance & admittance, the error will not beyond: | ΔX=±(X*2%+Y*2%+Dx) ΔY=±(X*2%+Y*2%+Dy) ΔX: basic error limit value of in-phase component ΔY: basic error limit value of Quadrature Component X: Indication absolute value of in-phase component Y: Indication absolute value of Quadrature Component Dx & Dy: Zero error and Quantizing Error When testing CT & PT, Dx,Dy=1(or 2)%*(Error limit value of CT & PT When testing Z & Y, Dx,Dy= 3 digits | 
Measure Range & Resolution
| CT PT class | Test Range | Resolution | ||
| In-phase component | Quadrature Component | In-phase component | Quadrature Component | |
| 0.01 | ±0.4000 | ±13.752 | 0.0001% | 0.001' | 
| 0.02 | ||||
| 0.05 | ||||
| 0.1 | ±4.000 | ±137.52 | 0.001% | 0.01' | 
| 0.2 | ||||
| 0.5 | ||||
| 1.0 | ±40.00 | ±999.9 | 0.01% | 0.1' | 
| Impedance Measure Range & Resolution | ||||
| Range | Measure Range (Ω) | Resolution | ||
| 5A | ±1.000 | 0.0001 | ||
| 1A | ±6.000 | 0.0001 | ||
| Admittance Measure Range & Resolution | ||||
| Range | Measure Range (mS) | Resolution | ||
| 100V | ±9.9999 | 0.0001 | ||
| 57.7V | ±9.9999 | 0.0001 | ||
Features
1) LCD display
2) Test of ratio, ratio error, phase angle error, impedance, admittance
3) Test data values are all displayed
4) Used for testing of class 1 to 0.01 instrument transformer with rated current 5A and 1A,
rated voltage 100V, 100V√3V
5) Display ratio error & phase angle error of all test points under rated burden or lower limit
burden 1%-120% Rated current or 20%-120% rated voltage

Design for options
|   | 
| Phase Angle Error CT PT Test Set Images | 
 CT PT 220KV Portable Test Equipment With PC Communication Interface
                                                                                    
                        
                        
                        
                                                            CT PT 220KV Portable Test Equipment With PC Communication Interface
                                                    
                        
                     Cabinet Type CT PT Test Equipment System Error Measurement
                                                                                    
                        
                        
                        
                                                            Cabinet Type CT PT Test Equipment System Error Measurement
                                                    
                        
                     0.01 PT Potential Transformer , Lab Current And Potential Transformers
                                                                                    
                        
                        
                        
                                                            0.01 PT Potential Transformer , Lab Current And Potential Transformers
                                                    
                        
                     0.02 Class CT PT Test Equipment , Low Current CT Test Kit
                                                                                    
                        
                        
                        
                                                            0.02 Class CT PT Test Equipment , Low Current CT Test Kit
                                                    
                        
                     4000A Current Transformer Tester In Magnetic Environment
                                                                                    
                        
                        
                        
                                                            4000A Current Transformer Tester In Magnetic Environment
                                                    
                        
                     0.05% CT PT Test Equipment Phase Angle Error Measurement
                                                                                    
                        
                        
                        
                                                            0.05% CT PT Test Equipment Phase Angle Error Measurement
                                                    
                        
                     0.2 Class CT PT Test Equipment Electromagnetic Type VT
                                                                                    
                        
                        
                        
                                                            0.2 Class CT PT Test Equipment Electromagnetic Type VT
                                                    
                        
                     0.02 Class CT PT Test Equipment
                                                                                    
                        
                        
                        
                                                            0.02 Class CT PT Test Equipment
                                                    
                        
                     0.05S CT PT Analyzer
                                                                                    
                        
                        
                        
                                                            0.05S CT PT Analyzer
                                                    
                        
                     100V CT PT Test Equipment , 15A Current Transformer Analyzer
                                                                                    
                        
                        
                        
                                                            100V CT PT Test Equipment , 15A Current Transformer Analyzer